5.10 ekey net System Part Numbers
When choosing a particular ekey net system the following options need to be considered:
c. Scanner type (wall mount or integra), capacity (40, 200, 2000), color (black, white, accessories), and
mounting accessories (surface mount, dry-wall, rough-in, box).
d. Interface and control (relay, Crestron, Wiegand);
DESCRIPTION
SCANNER CAPACITY, TYPE, COLOR,
& MOUNTING ACCESSORIES
Wall mount scanner (surface mount)
Available in Anthracite (black); silver-metallic
Scanner capacity 40, 200, 2000 fingerprint template
Mounts directly on the surface through special bracket (that is
included) using two screws
integra scanner (flush mount)
The scanner body itself is Anthracite (black) only.
Scanner capacity 40, 200, 2000 fingerprint template
Color Options & Mounting Accessories**:
Design Elementsavailable in White, Brush Steel, or Golden
colors (these snap over the scanner as decorative cover plate).
Wall Trims available in Almond, Black, Brown, Ivory, or White
(these are Decora Wall Plate with special cut to fit the integra
scanner); also in stainless steel.
Mounting Bracketsintegra scanner does not fit into wall mount
single gang box. Special brackets are available depending on the
substrate (drywall, studs rough-in, block, or directly into cut-in
opening) where the integra scanner will be mounted.
** These are ordered separately. Refer to ekey integra Scanner
Accessories for part numbers & details
CONTROL UNIT TYPE &
RELAYS
Wall mount control (surface mount)
3 relays (dry contact with Common, normal open/normal close)
Mounts directly on the surface through din rail bracket (that is
included) using two screws
Mini (DIN Rail mount)
1 relay solid state
Mounts directly on the surface through din rail bracket (that is
included) using two screws
Extended Control Unit (DIN Rail Mount)
3 relay. Works only when connected with ekey net CP mini 1 or ekey
net CP mini 2 or ekey net CP DRM 4 to s erve s as the base for the
composite control panel.