5
ekey home wiring
Cable recommendation
J-Y(ST)Y 4 x 2 x 0.8
Wire assignment:
2x RS485 bus; 2x RS485 back-up wires
2x power supply; 2x back-up wires for increased
cross section when cable length is above 50m
Power supplies
ekey home
control panels
ekey home
ngerscanners
RS485: serial
wiring (in a line)
max. 500m
RS485: serial
wiring (in a line)
max. 500m
RS485: serial
wiring (in a line)
max. 500m
FS WM 2.0
FS IN 2.0
FS OM
CP WM
CP mini
CP DRM
Safety isolating
transformer,
protection class II
(SELV)